Reference: ELEE01265
Activation electromagnets ER20/C
Features:
Protection rate: IP00
Insulation class: B (130ºC)
Cycle duration: 2 minutes
Standard stroke "s": 5mm
Temperature rise "DV31": 70ºC
Work: Pull/Push
Incorporated return spring: YES
|
Duty-cycle ED(%) |
100 |
40 |
25 |
15 |
5 |
| Abs. Power at 20ºC (W) | 5.5 | 11 | 16 | 24 | 60 |
| Minimum force (N) | 0.8 | 2.1 | 2.8 | 4.1 | 6.8 |
| Max time under voltage(s) | ∞ | 48 | 30 | 18 | 6 |
| Plunger weight (g) | 12 | ||||
| Solenoid weight (g) | 45 | ||||
|
Duty-cycle ED(%) |
Standard voltages |
Under demand voltages |
|||||||||||
|
VDC |
VAC |
VDC |
VAC |
||||||||||
|
6 |
12 |
24 |
48 |
100 |
125 |
205 |
110 |
230 |
Min |
Max |
Min |
Max |
|
| 100% | O | O | O | O | X | X | X | X | X | 3 | 85 | X | X |
| 40% | O | O | O | O | O | O | X | X | X | 3 | 125 | X | X |
| 25% | O | O | O | O | O | O | X | X | X | 3 | 150 | X | X |
| 15% | O | O | O | O | O | O | X | X | X | 4 | 180 | X | X |
| 5% | O | O | O | O | O | O | O | X | X | 6 | 230 | X | X |
Layout: O= Available; X= Unavailable